Robotics paper index
KAISEN: Reproducible Subgroup Fairness Auditing for Clinical Risk Models
One-line summary
A robotics research paper on KAISEN: Reproducible Subgroup Fairness Auditing for Clinical Risk Models.
Engineering notes
Engineering notes will be added by the Robot Papers editorial team.
Chinese explanation / 中文解读
中文解读待补充:本站会优先为 VLA、具身智能、人形机器人控制、机器人操作等高价值论文补充中文说明。
Original abstract
Clinical risk models routinely achieve strong aggregate performance while producing materially different error rates across patient subgroups. Audit pipelines have been proposed to catch this, but their components are rarely stress-tested, so it is unclear which parts of an audit can be trusted and under what conditions. We present KAISEN, a five-phase audit pipeline covering subgroup stratification, disparity measurement, mechanism diagnostics, post-hoc mitigation, and drift monitoring, evaluated to the point of failure on a synthetic benchmark of 16 disease tasks, 15 social-determinant axes from Healthy People 2030, and three prespecified intersections. Four findings follow. (i) Significance tracks each axis's gap against its own minimum detectable effect: rank correlation between significance count and raw equalized-odds difference (EOD) across the 15 axes is rho = 0.56, rising to rho = 0.78 once EOD is standardized by that floor. (ii) Per-group threshold optimization reduces EOD in 48 of 48 held-out runs (paired delta = -0.285, 95% CI [-0.313, -0.252]), while group-wise Platt scaling -- the better calibrator -- behaves as a coin flip on EOD (19 of 48 runs improved, 95% CI [0.26, 0.55]) with mean effect near zero, so what an audit should report is the variance, not the average. (iii) The mechanism diagnostic classifies 144 of 144 controlled cases correctly but recovers none of 48 model-driven cases under proxy misspecification, with no signal that it failed. (iv) CUSUM failures and false alarms track cohort realization far more than disease: at the reference threshold, all 27 false alarms and 7 of 8 missed shifts come from different seeds (chi-squared p = 0.002), so a threshold tuned on one cohort fails to transfer. All results are synthetic with known ground truth and do not establish clinical validity. Code, artifacts, and scripts reproducing every number are released.
Links and sources
Need this topic turned into a technical roadmap?
Robot Papers can prepare a custom robotics literature review, code map, dataset map, and B2B technology assessment.
Request B2B research
Comments